Please use this identifier to cite or link to this item:
http://gukir.inflibnet.ac.in:8080/jspui/handle/123456789/5178
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Parvathi C.S | |
dc.contributor.author | Bhaskar P | |
dc.contributor.author | Kulkarni A.B. | |
dc.date.accessioned | 2020-06-12T15:06:23Z | - |
dc.date.available | 2020-06-12T15:06:23Z | - |
dc.date.issued | 2004 | |
dc.identifier.citation | IETE Technical Review (Institution of Electronics and Telecommunication Engineers, India) , Vol. 21 , 4 , p. 291 - 298 | en_US |
dc.identifier.uri | 10.1080/02564602.2004.11417156 | |
dc.identifier.uri | http://gukir.inflibnet.ac.in:8080/jspui/handle/123456789/5178 | - |
dc.description.abstract | The effect of sampling rate on the performance of Fuzzy Logic Controller (FLC) for the speed control of DC motor has been studied in this paper. A seven number triangular membership function for fuzzification, IF-THEN rules for decision-making logic and Center of Gravity (COG) for defuzzification have been used for the FLC. Experimental setup has been made up of DC micro-motor, LabVIEW software package, Signal Conditioning extension for Instrumentation (SCXI) cards, Data Acquisition (DAQ) board and Fuzzy logic toolkit. The speed control of DC motor was done for a sampling time of 1 second, 3 seconds, 5 seconds. For slower sampling rate the response of DC motor becomes sluggish and oscillations are observed at the set point. © 2004 Taylor & Francis Group, LLC. | en_US |
dc.title | Effect of sampling rate on the performance of fuzzy logic controller for the speed control of dc motor | en_US |
dc.type | Article | |
Appears in Collections: | 1. Journal Articles |
Files in This Item:
There are no files associated with this item.
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.