Please use this identifier to cite or link to this item:
http://gukir.inflibnet.ac.in:8080/jspui/handle/123456789/3689
Title: | Design of sensor setup and study of humidity sensing behaviour of conducting polyaniline I ceramic composites |
Authors: | Machappa T Anilkumar K.R Sasikala M Prasad M.V.N.A. |
Keywords: | Ceramics Humidity sensor Polyaniline Time response |
Issue Date: | 2008 |
Citation: | Proceedings of the 3rd International Conference on Sensing Technology, ICST 2008 , Vol. , , p. 284 - 288 |
Abstract: | Sensor setup for the measurement of humidity was designed using square glass chamber provided with sample holder, vaporizer, hygrometer and temperature display. Using this set up, authors have studied the response time of the sensor setup and humidity sensing properties for Polyaniline (PANI) and PANI / Sodium metavanadate (NaV03) composites. The variation in electrical resistance with change in relative humidity (RR) in the range between 20 to 95% of RH is reported and this may be due to change in surface electrical resistance. The variation in resistance and hence conductivity depends on capillary condensation ofwater causing ionic conductivity within the sensing materials. © 2008 IEEE. |
URI: | 10.1109/ICSENST.2008.4757114 http://gukir.inflibnet.ac.in:8080/jspui/handle/123456789/3689 |