Please use this identifier to cite or link to this item: http://gukir.inflibnet.ac.in:8080/jspui/handle/123456789/4677
Title: Visual Enhancement of Digital Ultrasound Images Using Multiscale Wavelet Domain
Authors: Hiremath P.S
Akkasaligar P.T
Badiger S.
Keywords: despeckling
shrinkage rule
thresholding
ultrasound image
wavelet transform
Issue Date: 2010
Citation: Pattern Recognition and Image Analysis , Vol. 20 , 3 , p. 303 - 315
Abstract: Ultrasonography has been considered as one of the most powerful techniques for imaging organs and soft tissue structures in the human body. The main disadvantage of medical ultrasonography is the poor quality of images, which are affected by multiplicative speckle noise. In this paper, we present a novel method for despeckling medical ultrasound images. The primary goal of speckle reduction is to remove the speckle without losing much detail contained in an image. To achieve this goal, we make use of the wavelet transform and apply multi-resolution analysis to localize an image into different frequency components or useful subbands and then effectively reduce the speckle in the subbands according to the local statistics within the bands. The main advantage of the wavelet transform is that the image fidelity after reconstruction is visually lossless. The objective of the paper is to investigate the proper selection of wavelet filters and thresholding schemes which yields optimal visual enhancement of ultrasound images, in particular. We employ the wavelet shrinkage denoising techniques with different wavelet bases and decomposition levels on the individual subbands to achieve the best acceptable speckle reduction while maintaining the fidelity of the image and also examine the effects of different thresholding techniques as well as shrinkage rules for denoising ultrasound images. The proposed method consists of the log transformed original ultrasound image being subjected to wavelet transform, which is then denoised by a thresholding technique using a shrinkage rule. Experimental results show that the subband decomposition of ultrasound images, using Bior6.8 and level 3 with soft thresholding based on Bayes shrinkage rule, performs better than other techniques. The performance is measured in terms of Variance, Mean Square Error (MSE), Signal-to-Noise Ratio (SNR), Peak SNR (PSNR) and Correlation Coefficient (CC). The results of wavelet shrinkage techniques are compared with common speckle filters. We observe that the proposed method achieves better visual enhancement of ultrasound images which would lead to more accurate image analysis by the medical experts. © 2010 Pleiades Publishing, Ltd.
URI: 10.1134/S1054661810030065
http://gukir.inflibnet.ac.in:8080/jspui/handle/123456789/4677
Appears in Collections:1. Journal Articles

Files in This Item:
There are no files associated with this item.


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.